This is the latest recevied telemetry packets stored in our database for station/object CE4ERM-13. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Celsius* | Rel_Hum* | Atm_Press* | Value4* | Value5* |
|---|---|---|---|---|---|
| 1794336572 | 28 C | 24.41 % | 1020.38 hPa | 0 | 0 |
| 1794335968 | 28 C | 23.14 % | 1020 hPa | 0 | 0 |
| 1794335364 | 27.4 C | 23.62 % | 1020 hPa | 0 | 0 |
| 1794334760 | 27.6 C | 22.29 % | 1020.25 hPa | 0 | 0 |
| 1794334156 | 28.1 C | 23.6 % | 1020.13 hPa | 0 | 0 |
| 1794333552 | 27.4 C | 24.37 % | 1021.5 hPa | 0 | 0 |
| 1794332948 | 27.2 C | 23.62 % | 1020.25 hPa | 0 | 0 |
| 1794332344 | 26.3 C | 25.03 % | 1020.63 hPa | 0 | 0 |
| 1794331740 | 26.4 C | 25.26 % | 1019.88 hPa | 0 | 0 |
| 1794331136 | 26.7 C | 25.5 % | 1020.13 hPa | 0 | 0 |
| 1794330532 | 25.8 C | 26.97 % | 1021.13 hPa | 0 | 0 |
| 1794329928 | 24.5 C | 29.59 % | 1021.38 hPa | 0 | 0 |
| 1794329324 | 24.1 C | 30.25 % | 1021.25 hPa | 0 | 0 |
| 1794328720 | 25.2 C | 28.06 % | 1021.63 hPa | 0 | 0 |
| 1794328116 | 25.6 C | 29.58 % | 1021.13 hPa | 0 | 0 |
| 1794327512 | 24.8 C | 30.99 % | 1022.38 hPa | 0 | 0 |
| 1794326908 | 23.1 C | 33.76 % | 1022.5 hPa | 0 | 0 |
| 1794326304 | 23.3 C | 35.29 % | 1022.38 hPa | 0 | 0 |
| 1794325700 | 22.5 C | 35.88 % | 1022.5 hPa | 0 | 0 |
| 1794325096 | 20.5 C | 38.21 % | 1023 hPa | 0 | 0 |
| 1794324492 | 21 C | 36.59 % | 1022.63 hPa | 0 | 0 |
| 1794323888 | 20.9 C | 36.11 % | 1024.25 hPa | 0 | 0 |
| 1794323284 | 20.1 C | 37.82 % | 1022.88 hPa | 0 | 0 |
| 1794322680 | 21.4 C | 35.33 % | 1021.88 hPa | 0 | 0 |
| 1794322078 | 21.9 C | 35.12 % | 1021.13 hPa | 0 | 0 |
*Used Equation Coefficients:
Celsius: 0, 0.1, -50
Rel_Hum: 0, 0.01, 0
Atm_Press: 0, 0.125, 0
Value4: 0, 1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)