This is the latest recevied telemetry packets stored in our database for station/object KY1N-12. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Battery* | Temp* | Value3* | Value4* | Value5* |
|---|---|---|---|---|---|
| 1792726398 | 439 Volts | 585 Deg.F | 0 | 0 | 0 |
| 1792725500 | 439 Volts | 586 Deg.F | 0 | 0 | 0 |
| 1792724602 | 439 Volts | 587 Deg.F | 0 | 0 | 0 |
| 1792723705 | 439 Volts | 587 Deg.F | 0 | 0 | 0 |
| 1792721909 | 440 Volts | 589 Deg.F | 0 | 0 | 0 |
| 1792716523 | 441 Volts | 593 Deg.F | 0 | 0 | 0 |
| 1792714727 | 441 Volts | 595 Deg.F | 0 | 0 | 0 |
| 1792713829 | 442 Volts | 595 Deg.F | 0 | 0 | 0 |
| 1792712932 | 442 Volts | 596 Deg.F | 0 | 0 | 0 |
| 1792712034 | 443 Volts | 597 Deg.F | 0 | 0 | 0 |
| 1792711137 | 443 Volts | 598 Deg.F | 0 | 0 | 0 |
| 1792710239 | 443 Volts | 598 Deg.F | 0 | 0 | 0 |
| 1792709342 | 443 Volts | 599 Deg.F | 0 | 0 | 0 |
| 1792708445 | 443 Volts | 600 Deg.F | 0 | 0 | 0 |
| 1792707547 | 443 Volts | 601 Deg.F | 0 | 0 | 0 |
| 1792706649 | 444 Volts | 601 Deg.F | 0 | 0 | 0 |
| 1792703058 | 445 Volts | 604 Deg.F | 0 | 0 | 0 |
| 1792701263 | 447 Volts | 606 Deg.F | 0 | 0 | 0 |
| 1792700365 | 447 Volts | 608 Deg.F | 0 | 0 | 0 |
| 1792699466 | 449 Volts | 610 Deg.F | 0 | 0 | 0 |
| 1792698518 | 492 Volts | 613 Deg.F | 0 | 0 | 0 |
| 1792698514 | 492 Volts | 613 Deg.F | 0 | 0 | 0 |
| 1792698476 | 487 Volts | 613 Deg.F | 0 | 0 | 0 |
| 1792698380 | 492 Volts | 612 Deg.F | 0 | 0 | 0 |
| 1792698179 | 496 Volts | 611 Deg.F | 0 | 0 | 0 |
*Used Equation Coefficients:
Battery: 0, 1, 0
Temp: 0, 1, 0
Value3: 0, 1, 0
Value4: 0, 1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)